Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Natal; s.n; 2021. 59 p. tab, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1537222

RESUMO

Os instrumentos endodônticos de níquel-titânio acionados a motor foram desenvolvidos para se obter um preparo químico-mecânico mais rápido e seguro, no entanto, esses instrumentos apresentam como desvantagem o risco de fraturar durante o seu uso. Diante disso, os fabricantes têm desenvolvido mudanças no design dos instrumentos, nos acabamentos das ligas e na cinemática de uso, pois são características que contribuem para que as fraturas aconteçam. O objetivo deste estudo foi avaliar e comparar propriedades mecânicas de novos instrumentos de níquel-titânio com memória controlada lançados no mercado. Os sistemas WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland), WA1 File (WA1; TDKaFile, Cidade do México, México) e X1 File (X1; MK Life, Porto Alegre, RS, Brasil) foram submetidos ao teste de resistência à torção, de acordo com a norma ISO 3630-1, ao teste rigidez à flexão, através do ensaio de flexão em cantiléver (45º) e ao teste de resistência à flambagem. Os resultados foram avaliados através da análise de variância (ANOVA), o teste F e o teste de Tukey, considerando um nível de significância de 5%. No teste de resistência à torção os instrumentos WOG apresentaram maior deflexão angular, ou seja, maior resistência à fratura em torção, enquanto os instrumentos WA1 a menor e na comparação do torque máximo em torção não houve diferença estatística significante entre os sistemas. Nos testes de rigidez a flexão e resistência à flambagem houve diferença estatística significante entre os 3 sistemas, sendo os instrumentos X1 os mais rígidos. No primeiro teste os instrumentos WA1 se apresentaram como os mais flexíveis e no segundo, os instrumentos WOG. Conclui-se que os instrumentos WOG, WA1 e X1 mostraram diferenças estatísticas nos testes mecânicos, sendo os instrumentos WOG e WA1 os mais resistentes à fratura por torção e os mais flexíveis, diferentemente dos instrumentos X1 que se apresentaram mais susceptíveis à fratura por torção e menos flexíveis (AU)


Reciprocating nickel-titanium endodontic instruments have been developed to obtain a faster and safer preparation, however, these instruments have the disadvantage of fracturing during use. Facing this disadvantage, manufacturers have developed changes in instrument design and alloy finishes, as metallurgical characteristics are one of the factors that contribute to fractures. The aim of this study was to evaluate and compare mechanical properties of new nickel-titanium instruments with controlled memory. The WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland), WA1 File (WA1; TDKaFile, Mexico City, Mexico) and X1 File (X1; MK Life, Porto Alegre, RS, Brazil) systems were subjected to the torsional fatigue test, according to the ISO 3630-1 standard, flexural stiffness test, through the cantilever flexion test (45°) and buckling resistance test. The results were evaluated through analysis of variance (ANOVA), the F test and the Tukey test, considering a significance level of 5%. In the torsional fatigue test, the WOG instruments showed greater angular deflection, that is, greater resistance to torsional fracture and the WA1 instruments the lesser, and when comparing the maximum torsional torque, there was no statistically significant difference between the systems. In the flexural stiffness and buckling resistance tests, there was a statistically significant difference between the 3 systems, with the X1 instruments being the most rigid. In the first test, the WA1 instruments were the most flexible followed by the WOG instruments. In conclusion, the WOG, WA1 and X1 instruments showed differences in the mechanical tests, with the WOG and WA1 instruments being the most resistant to torsion fracture and the most flexible, unlike the X1 instruments that were more susceptible to torsion fracture and also the most rigid (AU).


Assuntos
Instrumentos Odontológicos , Resistência à Flexão , Testes Mecânicos , Análise de Variância , Microscopia Eletrônica de Volume
2.
Natal; s.n; 2019. 105 p. ilus, graf, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1537504

RESUMO

O retratamento endodôntico é um procedimento realizado quando o tratamento anterior tem insucesso e visa reverter os processos infecciosos, removendo completamente o material obturador permitindo uma nova limpeza, modelagem e reobturação dos canais radiculares. Com vistas a melhoria das taxas de sucesso e eficiência do retratamento, vários sistemas de níquel-titânio (NiTi) têm sido desenvolvidos com a utilização de apenas um instrumento por meio de um movimento reciprocante, levantado novas perspectivas para o preparo biomecânico do canal radicular, bem como, o retratamento. Portanto, este estudo teve por objetivo analisar a produção de desvio e capacidade de limpeza durante retratamento dos canais mesiais de molares inferiores com curvaturas severas (30° e 70°), obturados com BioC Sealer após utilização dos sistemas reciprocantes. Uma amostra de sessenta molares inferiores foi dividida em quatro grupos experimentais, assim distribuídos: G1- X1-Blue (25.06); G2- WaveOne Gold Primary (25.07); G3- Reciproc Blue (25.08); G4- WA1 (25.07). Cada grupo continha 15 molares, totalizando 120 canais mesiais, os quais passaram pela aquisição e processamento das imagens iniciais no Microtomográfo, para que posteriormente, fosse realizado o pareamento dos grupos. Todos os grupos foram instrumentados com o sistema de rotação continua Pro Taper Next. Após instrumentação, foram obturados com cone de guta percha ProTaper Universal, selados e colocados em estufa a 37 °C, 100% de umidade durante 72 horas. Para análise de desvio e remoção da obturação dos canais as amostras foram escaneadas por meio da Microtomografia (MicroCT). Por fim, foi avaliado e medido o desvio apical através da comparação das imagens dos canais obtidas pelas Micro-CT após o retratamento, bem como a remoção do material obturador, para posterior análise estatística. Os resultados quanto a produção de desvio após remoção do material obturador, entre grupos, demonstrou não haver diferença estatisticamente significante tanto para os canais radiculares mesio vestibulares como para os canais mesio linguais (p > 0,05). Na análise intra grupo, não houve diferença em relação aos grupos G1(X1 Blue), G2 (Wave one Gold) e G3 (Reciproc Blue) (p > 0,05), porém o grupo G4 (WA1) apresentou diferença significante, mostrando maior grau de desvio no canal mesio lingual do que no mesio vestibular (p < 0,05). Com relação a remoção do material obturado, na análise entre grupo, para o canal Mesio vestibular, pode-se observar que em todos os grupos houve uma diminuição no sentido cervical para apical, porém, no grupo G4 (WA1) observou-se uma maior remoção tanto no terço médio quanto no apical. No terço cervical a maior remoção do material obturador ocorreu no grupo G2 (Wave one Gold), seguido do G4 (WA1), G3 (Reciproc Blue) e G1(X1 Blue). Para o canal mesio lingual, o grupo G4 (WA1) demonstrou uma maior estabilidade de remoção do material obturador em todos os terços. No terço cervical houve uma maior remoção do material obturador no grupo G2, seguido do G4, G3 e G1, já no terço médio foi no grupo G2, seguido do G1, G4 e G3. No terço apical, o grupo G4 promoveu maior capacidade de remoção de material obturador, seguido de G1, G2 e G3. Para comparação entre médias intragrupos, não houve diferença estatisticamente significante quando se comparou os terços cervical/médio para os Grupos G1 e G4 (tanto no canal Mesio vestibular como no mesio lingual) e terços médio/apical (apenas no canal Mesio lingual), porém, o terço apical foi observado uma maior dificuldade na remoção do material obturador. Conclui-se que a maiorias dos sistemas reciprocantes testados no retratamento promoveram desvio apical, porém o sistema WA1 foi capaz de produzir menos desvio no canal Mesio vestibular. Os sistemas reciprocantes utilizados foram capazes de remove grande parte do material obturador, mas não em sua totalidade, o terço apical foi o que mais dificultou a remoção do material obturador, porém, o sistema WA1 foi o que apresentou maior desempenho neste terço (AU).


Endodontic retreatment is a procedure performed when the previous treatment is unsuccessful and aims to reverse infectious processes, completely removing the shutter material allowing a new cleaning, modeling and reobturation of root canals. With a view to improving success rates and retreatment efficiency, several nickel-titanium (NiTi) systems have been developed with the use of only one instrument through a reciprocal movement, raising new perspectives for biomechanical preparation of the root canal, as well as retreatment. Therefore, this study aimed to analyze the production of deviation and cleaning capacity during retreatment of the mesiaal channels of lower molars with severe curvatures (30° and 70°), obtained with BioC Sealer after using reciprocating systems. A sample of sixty lower molars was divided into four experimental groups, thus distributed: G1- X1-Blue (25.06); G2- WaveOne Gold Primary (25.07); G3- Reciproc Blue (25.08); G4- WA1 (25.07). Each group contained 15 molars, totaling 120 mesiaal channels, which passed through the acquisition and processing of the initial images in the Microtomográfo, so that later, the pairing of the groups was performed. All groups have been instrumented with the continuous Rotation System Pro Taper Next. After instrumentation, they were filled with protaper universal percha gutcone, sealed and placed in a greenhouse at 37 °C, 100% humidity for 72 hours. For analysis of deviation and removal of the filling of the channels, the samples were scanned by microtomography (Micro-CT). Finally, apical deviation was evaluated and measured by comparing the images of the channels obtained by micro-CT after retreatment, as well as removal of the shutter material, for further statistical analysis. The results regarding the production of deviation after removal of the shutter material between groups, showed no statistically significant difference both for vestibular mesium root canals and for lingual mesio channels (p > 0.05). In the intra-group analysis, there was no difference in relation to groups G1(X1 Blue), G2 (Wave one Gold) and G3 (Reciproc Blue) (p > 0.05), but group G4 (WA1) showed a significant difference, showing a higher degree of deviation in the lingual mesium channel than in the vestibular mesium (p < 0.05). Regarding the removal of the obtained material, in the analysis between group, for the vestibular Mesio canal, it can be observed that in all groups there was a decrease in the cervical direction to apical, however, in group G4 (WA1) there was a greater removal in both the middle and apical third. In the cervical third the highest removal of the shutter material occurred in group G2 (Wave one Gold), followed by G4 (WA1), G3 (Reciproc Blue) and G1 (X1 Blue). For the lingual mesio channel, group G4 (WA1) demonstrated greater shutter material removal stability across all thirds. In the cervical third, there was a higher removal of the shutter material in group G2, followed by G4, G3 and G1, already in the middle third it was in group G2, followed by G1, G4 and G3. In the apical third, group G4 promoted higher shutter material removal capacity, followed by G1, G2 and G3. For comparison between intragroup means, there was no statistically significant difference when comparing the cervical/middle thirds for Groups G1 and G4 (both in the vestibular mesio channel and in the lingual mesium) and middle/apical thirds (only in the lingual Mesio canal), however, the apical third was observed a greater difficulty in removing the shutter material. It was concluded that most of the reciprocal systems tested in the retreatment promoted apical deviation, but the WA1 system was able to produce less deviation in the vestibular Mesio canal. The reciprocal systems used were able to remove much of the shutter material, but not in its entirety, the apical third was the one that most difficult to remove the shutter material, however, the WA1 system was the one that performed higher in this third (AU).


Assuntos
Humanos , Obturação do Canal Radicular/instrumentação , Preparo de Canal Radicular/instrumentação , Análise de Variância , Estatísticas não Paramétricas , Radiografia Dentária Digital/instrumentação , Retratamento , Microtomografia por Raio-X/instrumentação
3.
Bauru; s.n; 2018. 144 p. ilus, tab.
Tese em Inglês | LILACS, BBO - Odontologia | ID: biblio-884453

RESUMO

The aim of this study was to evaluate canal transportation; centering ability; dentin thickness; change in volume, and time spent on shaping ability of maxillary molars prepared with mechanized NiTi file systems composed of a conventional NiTi alloy (Mtwo), a CM-Wire (Prodesign R and Hyflex CM) NiTi alloy, R-phase (Twisted File Adaptive) and an M-Wire (Reciproc) NiTi alloy]. With the purpose of understanding the role of new treated NiTi alloys in larger apical preparations, this type of preparation was evaluated in the mesiobuccal (MB) and distobuccal canal (DB) of maxillary molars, as well as, in the second mesiobuccal (MB2) canals in extracted maxillary first molars by means of micro-computed tomographic (micro- CT) imaging. For the second mesiobuccal canal (MB2) evaluation, thirty maxillary molars with Vertucci type IV canal configuration were selected and randomly divided into 3 groups (n = 10): Reciproc [REC; VDW, Munich, Germany], Prodesign R [PDR; Easy, Belo Horizonte, Brazil] and Mtwo [MO; VDW, Munich, Germany]. To assess the mesiobuccal and distobuccal canals, a total of 45 extracted maxillary molars were selected according to the following criteria: MB canals exhibiting curvatures according to the Weine classification in the 20-30 degree range; and DB canals presenting curvatures in the 0-5 degree range. These teeth were randomly assigned to three groups, Reciproc (REC) [40.06]; Hyflex CM (HF) [40.06] [Coltene, Cuyahoga Falls, OH, USA] and Twisted file Adaptive (TFA) [35.04]. After root canal preparation, all the teeth were scanned to evaluate parameters previously cited. In particular, the percentage of negotiability of the MB2 canal was evaluated. All parameters were statistically compared using the Kruskal-Wallis and Dunn's Multiple comparison tests within groups with a significance level of 5%. For MB2 canals, no statistically significant difference was observed among the three groups with regard to the values of canal transportation, centering ability, remaining dentin thickness in the coronal third, number of specimens with thickness under 0.5 mm in the danger zone, and apical volume (P>0.05). However, the entire volume of the canal in Group MO differed statistically from that of Group PDR (P<0.05), but Group REC did not differ statistically from Groups MO and PDR (P>0.05). Group PDR demanded more time to reach WL than use of the MO and REC systems. For MB and DB canals, the trend of canal transportation was towards inner curvature in apical third, while in the coronal third it was towards the outer curve. There was no difference in apical transportation values in the first apical millimeters for both canals. In MB canal, at 3 and 4 mm, the Reciproc transportation value was significantly lower than that of Hyflex CM(P<0.05). In the DB canal, at 2 and 4 mm, Reciproc showed substantially higher values than Group TFA (P<0.05). There was no statistically significant difference between the two canals among the three systems for centering ability in the apical third and the remaining dentin thickness (RDT). For DB canal, there was no significant difference in shaping time, but in the MB canal, Group TFA was swifter than Reciproc and Hyflex CM. The initial changes in volume (apical/entire) after canal preparation was statistically significant within groups in MB and DB canals for percentage and volume of dentin removed. TFA had the lowest values for the apical and entire volumes of dentin removed in both canals compared with Reciproc and Hyflex CM (P<0.05). TFA had the lowest percentage of dentin removed from the entire MB canal, and from the apical and entire volume of DB canal. For negotiating and shaping the MB2 canal, the three file systems had similar performance. However, the REC system reached the full working length faster than PDR. The MO and REC systems removed more dentin in the inner furcation area when compared with PDR. For MB and BD canals, the heat treated NiTi alloy systems used for larger apical preparation evenly maintained the morphology of the MB and DB canals of maxillary molars. In shaping procedures, the larger apical preparation produced slight canal transportation without evidence of significant preparation errors. However, these variations may not be feasible of clinical significance. Use of TFA was swifter for preparing the MB canal and produced fewer changes in volume parameters. The TFA system was able to preserve the original canal anatomy with less canal transportation than the Reciproc and Hyflex CM systems.(AU)


O objetivo deste estudo foi avaliar o transporte do canal, a centralização do canal, a espessura dentinária, a alteração volumétrica e o tempo de trabalho de diferentes sistemas mecanizados de níquel-titânio compostos por ligas convencional (Mtwo) e tratados termicamente (CMWire (Prodesign R e Hyflex CM), M-Wire (Reciproc) e fase-R (Twisted file adaptive) em preparos de canais em molares superiores. O papel dos novos instrumentos de níquel titânio tratados termicamente em preparos apicais mais amplos de canais mésio-vestibulares e distovestibulares dos molares superiores foi avaliado, como também o preparo do canal mésiopalatino (CMP), por meio da microtomografia computadorizada (µ-CT). No estudo do canal mésio-palatino, 30 primeiros molares superiores com configuração tipo IV de Vertucci foram selecionados e divididos em 3 grupos (n = 10): Reciproc [REC; VDW, Munich, Germany], Prodesign R [PDR; Easy, Belo Horizonte, Brazil] and Mtwo [MO; VDW, Munich, Germany]. No estudo dos canais mésio-vestibulares e disto-vestibulares, o total de 45 molares superiores foram selecionados com angulação da raiz mésio vestibular de 20 a 30 graus e apresentando a raiz disto-vestibular com angulação de 0 a 5 graus, de acordo com a classificação de Weine. Os dentes foram aleatoriamente distribuídos em 3 grupos (n=15): Reciproc (40.06) [REC, VDW, Munich, Germany]; Hyflex CM (40.06) [HF, Coltene, Cuyahoga Falls, OH, USA]; e Twisted file Adaptive (35.04) [TFA, SybronEndo, Orange, CA]. Após o preparo dos canais mésio-palatino, mésio-vestibular, e disto-vestibular, todos os dentes foram escaneados para avaliação dos parâmetros previamente citados. Especificamente, na avaliação do canal mésiopalatino, foi avaliada a porcentagem de canais que alcançaram patência. Todos os parâmetros foram avaliados estatisticamente pelo teste de Kruskal-Wallis e pelo teste Dunn's de múltipla comparação entre grupos, com nível de significância de 5%. O canal mésio-palatino não apresentou diferença estatisticamente significante em relação ao transporte, centralização, remanescente de dentina no terço cervical, quanto ao número de espécime abaixo de 0,5 mm de espessura na zona de perigo e no volume apical (P>0.05). O volume total do canal no grupo MO diferenciou-se do volume total do grupo PDR (P<0.05), enquanto essa diferença não foi evidenciada entre os grupos REC comparado aos grupos MO e PDR (P>0.05). O grupo PDR demandou maior tempo para atingir o comprimento de trabalho comparado aos sistemas MO e REC. Na análise dos canais MV e DV dos molares superiores, o transporte coronal direcionou-se para o interior da curvatura do canal, enquanto no terço apical o transporte direcionou-se para o lado externo da curvatura. O transporte apical no primeiro milímetro de ambos os canais (MV e DV) foi equivalente entre os grupos (P>0.05). O canal MV apresentou nos níveis 3 e 4 mm transporte do grupo Reciproc significantemente menor do que no grupo Hyflex CM (P<0.05). Em relação ao transporte apical, no canal DV, nos milímetros 2 e 4 apicais do grupo Reciproc transportou significantemente mais comparado ao grupo TFA (P<0.05). Contudo, a centralização apical de ambos os canais e a quantidade de remanescente dentinário apical não se diferiram estatisticamente (P<0.05). O preparo do canal MV foi mais rápido com o sistema TFA comparado ao Reciproc e do Hyflex CM (P<0.05), enquanto no canal DV não foi evidenciado diferenças em relação ao tempo de preparo (P>0.05). A porcentagem e o volume de dentina removida em todo o canal e na região apical, após o preparo do canal apresentou diferenças significantes entre os grupos. O grupo TFA teve as menores porcentagens e valores de dentina removida no volume total do canal e no volume apical, em ambos os canais, comparado com os sistemas Reciproc e Hyflex CM (P<0.05). No canal MP, os três sistemas avaliados prepararam e patenciaram semelhantemente os canais MP. Contudo, o sistema Reciproc foi mais rápido para alcançar o comprimento de trabalho do que o sistema Prodesign R. Os grupos Mtwo e Reciproc removeram mais dentina na região voltada para o interior da furca quando comparado ao Prodesign R. Os sistemas compostos por ligas tratadas termicamente em preparos com maior ampliação apical mantiveram a morfologia dos canais MV e DV. Os sistemas promoveram discretos transportes, sem evidência de erros no preparo. Contudo, essas variações não são passíveis de significância clínica. O grupo do TFA foi mais rápido e promoveu menores alterações nos parâmetros volumétricos. O grupo do TFA foi capaz de preservar a anatomia original do canal com menor grau de transporte comparado ao Reciproc e Hyflex CM.(AU)


Assuntos
Humanos , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Instrumentos Odontológicos , Desenho de Equipamento , Dente Molar/diagnóstico por imagem , Valores de Referência , Reprodutibilidade dos Testes , Microtomografia por Raio-X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...